UNDERGROUND CONCRETE SURFACE PROTECTION- COAL TAR EPOXY COATING


COAL TAR EPOXY COATING-

Coal tar epoxy coating is a heavy-duty protective polymer that blends epoxy resins with coal tar pitch to form a tough, black, high-solids coating for steel and concrete surfaces. It is prized for its exceptional resistance to corrosion, chemicals, abrasion, and water, making it ideal for use in extremely corrosive and submerged environments like underground pipelines, sewage treatment plants, and marine infrastructure





COMPOSITION OF COAL TAR EPOXY



Field of Application -Corrosion resistant coating for concrete and metal structures such as: 
• Crude oil storage tanks / underground structures 
• Dams, Barrage gates, Penstocks. 
• Foundation walls and sumps. 
• sewage treatment plant, underground pipelines 
• Splash zones in docks & harbors

Application Methodology - 

Surface Preparation 
• Steel: blast cleaned to ISO-Sa21/2 and remove dust, flakes, oil, grease or other loose foreign particles. • In case of new concrete, ensure the concrete is at least 28 days old and remove any loose foreign particles by compressed air. 
• Ensure the ambient temperature is not less than 10 OC and not more than 40OC at the time of coating. • To avoid condensation of moisture onto the coating substrate prior to application, RH should not be above 80% and substrate temperature should be at least more than 3°C above Dew point.

Health and Safety information 
• This product contains coal tar. Avoid contact with eyes and skin.
• Wear suitable protective clothing such as overalls, goggles, dust mask and gloves. Ensure that there is adequate ventilation in the area where the product is being applied. 
• Do not breathe in vapour or spray mist. 
• This product is flammable. 
• Keep away from sources of ignition. 
• Take precautionary measures against static discharge. 
• In case of fire, blanket flames with foam, carbon dioxide or dry chemicals. 
• Eye protection during application is recommended. 
• In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. 
• In case of skin contact, wash with soap and plenty of water. Get medical attention if irritation develops or persists